Endocannabinoid Blood Tests: A Real Diagnostic by 2035?
Photo by kaboompics via Pexels.
A group of researchers drew fasting blood from people with gambling disorder and found their plasma anandamide ran higher than in healthy controls, with p = .002. It is the kind of result that makes a biomarker enthusiast sit up. It is also a result from one cohort, in one disorder, and no physician can order a test on that basis.
Getting from that finding to a clinical diagnostic means clearing three separate hurdles. First, can anandamide (AEA) and 2-arachidonoylglycerol (2-AG) be measured reliably, across labs and across collection conditions? Second, does the number mean something clinically, such as separating patients from non-patients or predicting who responds to treatment? Third, does acting on it improve outcomes? Most biomarkers die at the second or third gate, not the first.
A caution before going further. The evidence base I could verify for this piece is thin: one published study, with no confirmed publication date. I could not verify whether any regulator has cleared an AEA or 2-AG assay, whether consensus protocols exist, or what trials are running now. Everything about 2035 below is reasoned extrapolation from precedent, and I will mark where fact ends and projection begins.
Key takeaways
- A gambling disorder study found higher plasma anandamide (p = .002) but no 2-AG difference, showing the markers shift with disease, not that they diagnose it.
- Sample handling, fasting, and exercise swing endocannabinoid levels, so standardized pre-analytical protocols must come before any clinical cutoff.
- By 2035 the likeliest outcome is a narrow research or drug-trial tool, not a routine diagnostic; a broad clinical test needs validated, multi-site evidence.
What One Gambling Disorder Study Actually Shows
The study appeared in European Psychiatry. It measured fasting plasma AEA and 2-AG in people with gambling disorder and compared them with healthy controls. The authors also collected data on general psychopathology, emotion regulation, impulsivity, personality and neuropsychological function, using a semi-structured clinical interview and psychometric tests.
What the data actually shows: plasma AEA was higher in the gambling disorder group (p = .002), while 2-AG did not differ between groups. Both molecules were related to disorder severity. Structural equation modeling suggested that novelty-seeking mediated that relationship, meaning part of the link between endocannabinoid levels and severity ran through that personality trait.
That is a meaningful signal. It supports the idea that circulating endocannabinoids move with a psychiatric condition and with trait-level behavior, not just with random noise.
Here is what it does not show. The study, as retrieved, gives no diagnostic cutoff, no sensitivity, no specificity, and no evidence that the measure beats a clinical interview at identifying anyone. A group-mean difference can be statistically solid and still be useless for classifying an individual, because the distributions overlap. A cohort comparison asks whether averages differ; a diagnostic asks whether one person's number tells you something.
One practical note. The page I retrieved carried no publication date, so check how recent the paper is before treating it as the current state of play. Older single-cohort findings in this area often fail to replicate in larger samples, and replication is the main thing missing here.
The more useful reading is modest. This study is a reason to run the larger, pre-registered, multi-site version, not a reason to believe a test is near.
Why These Molecules Are Hard to Measure
AEA and 2-AG are lipid messengers. Cells make them on demand, they act close to where they are produced, and enzymes break them down quickly. Blood levels are therefore a faint, indirect readout of what is happening in a particular brain region or gut wall. Plasma may reflect adipose tissue, platelets, the liver and the gut as much as any circuit you care about.
Then come the pre-analytical variables. The gambling disorder study used fasting samples, which was a sensible control, because fasting, time of day and recent exercise are all known to shift circulating endocannabinoids. A sample drawn at 3 p.m. after a run is not comparable with one drawn at 8 a.m. after an overnight fast. In routine clinics, nobody controls for that.
2-AG is the more fragile of the two. After collection it can still be made or degraded inside the tube by cells and enzymes, and it can isomerize to a closely related form, so handling time and temperature can change the result. A sample that sits on a bench for an extra twenty minutes may no longer represent the patient. This is a plausible reason the study found a group difference in AEA and none in 2-AG, though that is my inference, not something the authors established.
The gold-standard method is liquid chromatography with tandem mass spectrometry (LC-MS/MS). It is sensitive and specific, but whether consensus protocols or shared reference ranges exist was not verified in this research, and anyone planning around this should check. Without shared ranges, a lab in one city cannot say whether a value is high.
The counter-case is fair. Other labile analytes have been tamed with strict collection rules: defined tube types, immediate chilling, fast centrifugation, and stabilizing additives. The same discipline could work here. The cost is friction. Every extra step at the clinic, such as fasting requirements, a cold chain and tight timing, narrows the number of settings where the test can realistically be used. A diagnostic that only works in a research hospital is a research tool.
From Research Marker to Clinical Test: The Regulatory Road

Photo by Media Dung via Pexels.
Any diagnostic has to clear three bars, and they are different bars.
- Analytical validity: does the assay measure what it claims to, accurately and reproducibly?
- Clinical validity: does the result track the condition or outcome of interest?
- Clinical utility: does using the result improve patient care?
The gambling disorder study gestures at the second bar in one population. It says nothing about the first or third.
Two regulatory routes are worth knowing. The FDA Biomarker Qualification Program works through a defined context of use, meaning a narrow statement of what the biomarker is for, in whom, and for what decision. Laboratory-developed tests under CLIA are the other route, where a single lab validates and offers its own assay. I have described these in general terms; current rules, including recent changes to how laboratory-developed tests are overseen, need to be verified by anyone building a business plan.
Whether any regulator has cleared or accepted an AEA or 2-AG assay for clinical use was not verified. I am saying so plainly because the absence of confirmation is not evidence of a pipeline, and nothing here should be read as implying one exists.
For precedent, look at HbA1c. The key diabetes trials established that the measure mattered clinically, but results were not comparable across labs until dedicated standardization programs were built afterward. That effort took years of coordination between manufacturers, reference labs and professional bodies, and it came after the clinical case was already made. Endocannabinoids start with a weaker clinical case and a harder analyte.
If that pattern holds, multi-site standardization alone could plausibly consume a large share of a 7-15 year window. That is reasoned extrapolation, not a measured timeline. It also assumes funders and industry see enough payoff to pay for the unglamorous work of reference materials and ring trials, and that is not guaranteed.
The Deficiency Hypothesis: Where a Test Might Matter
The strongest conceptual argument for a test comes from clinical endocannabinoid deficiency, a hypothesis proposed in the early 2000s. It suggests that low endocannabinoid tone could underlie conditions such as migraine, fibromyalgia and irritable bowel syndrome, which share features like heightened pain sensitivity and a lack of clear structural pathology.
I could not verify the current evidentiary status of this idea. Treat it as an open hypothesis, and read recent systematic reviews before forming a view; they will say more than I can here.
The case for a test runs like this. If low tone is real in a subgroup of patients, an assay could stratify them, pointing to people who might respond to cannabinoid therapy or to drugs that raise endocannabinoid levels by blocking their breakdown. Stratification is how many biomarkers earn their keep: they do not diagnose the disease, they sort the patients.
The counter-case is substantial. Blood levels may not mirror brain or gut tone at all, given how local these signals are. And the gambling disorder result cuts against a simple story: AEA was higher in patients, not lower. Direction evidently varies by condition, and probably by tissue, stage and medication. A single deficiency number that applies across disorders looks unlikely on that evidence.
The more speculative read is that the first realistic use is subgrouping within a single disorder, for example separating migraine patients with unusually low circulating AEA from those without, rather than screening the general population for endocannabinoid deficiency. A narrow question with a defined context of use is also the shape regulators prefer.
What would give this credibility is boring: pre-registered cohorts, replication in independent samples, and agreement on whether plasma is even the right compartment. Until then, deficiency is a useful research frame, not a diagnosis a doctor can confirm.
Drug Development as the Pull Factor: FAAH and MAGL
Photo by CDC via Unsplash.
Two enzymes anchor the pharmacology. Fatty acid amide hydrolase (FAAH) breaks down AEA, and monoacylglycerol lipase (MAGL) breaks down 2-AG. Inhibitors of each are designed to raise the matching signal, which makes a plasma assay a natural pharmacodynamic readout: give the drug, measure whether the substrate rose.
That matters because biomarkers often enter medicine as trial tools before they ever become diagnostics. A drug developer needs proof that a molecule hit its target, and a blood measure that moves in the expected direction supplies it. Over time, the same assay may get validated well enough to guide treatment choices. If a pull comes for endocannabinoid assays by 2035, it most likely comes from here.
The safety history complicates the picture. A trial of the FAAH inhibitor BIA 10-2474 in France ended with a death and several hospitalizations. The event chilled the field and made regulators and sponsors more cautious. I am giving the outline from memory; the precise details, including what investigators concluded about causes, should be verified against primary reports before anyone cites them. A commonly drawn lesson is that the compound's off-target activity, not FAAH inhibition itself, was implicated, but check that rather than taking it from me.
Current FAAH and MAGL inhibitor trials, and any programs that link an assay to a drug, were not verified. ClinicalTrials.gov is the place to look, searching on the enzyme names and on anandamide and 2-AG plasma measurements.
The counter-case is straightforward. If inhibitor programs stall, whether from safety worries, disappointing efficacy or shifting investor appetite, the commercial reason to build a validated assay weakens sharply. Nobody funds multi-site standardization for a marker with no drug attached. The diagnostic's fate is tied to a pharmaceutical pipeline whose health I could not confirm.
Business Opportunities, and the Consumer Test Trap
If a validated assay emerges, where is the money? Two niches look plausible. Contract research labs could offer validated LC-MS/MS panels for trials, selling reliability to sponsors who need defensible target-engagement data. Collection-kit makers could solve the stabilization problem described earlier, with tubes, additives and shipping protocols that keep 2-AG from drifting between draw and analysis. Both are picks-and-shovels businesses, and both depend on the research demand actually materializing.
Whether any company currently sells endocannabinoid blood tests directly to consumers was not verified. Treat that as something to check, not assume, before pitching or competing.
The risk is the consumer test trap. A direct-to-consumer panel without validated reference ranges sells a number nobody can interpret. A customer receiving a value labeled low or high would have no evidence that the label means anything, or that any action follows from it. That invites regulatory scrutiny and, perhaps more damaging, credibility loss for the entire category.
The cannabis industry is the obvious temptation. Heavy cannabis use alters endocannabinoid signaling, so a test could easily be pitched to consumers as a way to read their own system, or to choose products. The evidence that this would lead to useful action is absent, as far as I could establish. Dispensary staff would be handed a number they cannot translate into a recommendation.
The speculative read is that credibility will come from partnerships with academic labs and clinical trials rather than marketing. A company that can point to peer-reviewed validation, published reference ranges and a regulator-facing context of use has something to sell. A company with a slick report and no data has a liability. In a field this young, the second kind will likely appear first, and the first kind will take years longer.
Three Scenarios for 2035

Photo by Edward Jenner via Pexels.
These scenarios are reasoned from precedent, not drawn from a sourced roadmap. I found no expert-supplied 2035 timeline, and anyone claiming one should be asked for the evidence.
| Scenario | What exists in 2035 | What it needs |
|---|---|---|
| 1. Most plausible | Research and trial tool confirming drug target engagement; no routine clinical use | Validated LC-MS/MS methods in a few expert labs; active inhibitor trials |
| 2. Possible | Validated assay for one narrow indication | Multi-site studies, a defined context of use, standardized sample handling first |
| 3. Least likely | Broad endocannabinoid tone panel in primary care | Proven utility, shared reference ranges, reimbursement |
Scenario one is the default because it asks the least. A few specialized labs can control handling tightly, and the user, a drug sponsor, cares about change within a person, not an absolute cutoff. That sidesteps the reference-range problem.
Scenario two requires the sample-handling issue to be solved before anything else, then replicated cohorts, then a regulator-accepted context of use. Given the HbA1c-style precedent, it is feasible within 15 years but tight within 7.
Scenario three would need all of that plus evidence that acting on the number improves outcomes, plus payers willing to cover it. The gambling disorder finding of higher AEA, not lower, is a small reminder of how far a one-size panel sits from the data.
Four things would shift the odds. A consensus collection and analysis protocol would raise them. So would a large replicated cohort and a successful inhibitor trial. Another safety setback in the enzyme-inhibitor field would lower them, by removing the commercial engine that pays for validation.
For 2035, my read is a conditional yes for narrow research uses and a probable no for a general diagnostic. The deciding factor is standardization rather than discovery. The biology looks real enough to keep studying; what is missing is a way to make a number from one lab mean the same thing in another.
Three signals are worth watching. First, a consensus pre-analytical protocol that spells out fasting, timing, temperature and stabilization. Second, replicated multi-site cohorts that confirm single-study findings like the gambling disorder result. Third, a drug trial that uses the assay as a formal endpoint. If all three show up, the 2035 picture improves. If none does, expect the same promising papers and the same missing test.
Sources
- Anandamide and 2-arachidonoylglycerol baseline plasma concentrations and their clinical correlate in gambling disorder
- Elevated plasma anandamide levels in sclerotic chronic graft-versus-host disease highlight the endocannabinoid system as a potential therapeutic target
- Anandamide and 2-arachidonoylglycerol baseline plasma concentrations and their clinical correlate in gambling disorder - PMC
- Anandamide and 2-arachidonoylglycerol baseline plasma concentrations and their clinical correlate in gambling disorder - PubMed
- (PDF) Anandamide and 2-arachidonoylglycerol baseline plasma concentrations and their clinical correlate in gambling disorder
- Individual Differences in Drug Response